pypowsybl.network.create_lcc_converter_station_bay#

create_lcc_converter_station_bay(network, df=None, raise_exception=True, reporter=None, report_node=None, **kwargs)[source]#

Creates a lcc converter station, connects it to the network on a given bus or busbar section and creates the associated topology.

Parameters:
  • network (Network) – the network to which we want to add the lcc converter station

  • df (DataFrame | None) – Attributes as a dataframe.

  • raise_exception (bool) – optionally, whether the calculation should throw exceptions. In any case, errors will be logged. Default is True.

  • reporter (ReportNode | None) – deprecated, use report_node instead

  • report_node (ReportNode | None) – optionally, the reporter to be used to create an execution report, default is None (no report).

  • kwargs (_SupportsArray[dtype[Any]] | _NestedSequence[_SupportsArray[dtype[Any]]] | bool | int | float | complex | str | bytes | _NestedSequence[bool | int | float | complex | str | bytes]) – the data to be selected, as named arguments.

Return type:

None

Notes

The voltage level containing the busbar section can be described in node/breaker or bus/breaker topology. If the voltage level is node/breaker, the lcc converter station is connected to the busbar with a breaker and a closed disconnector. If the network has position extensions, the lcc converter station will also be connected to every parallel busbar section with an open disconnector. If the voltage level is bus/breaker, the lcc converter station is just connected to the bus.

Valid attributes are:

  • id: the identifier of the new station

  • name: an optional human-readable name

  • power_factor: the power factor (ratio of the active power to the apparent power)

  • loss_factor: the loss factor of the station

  • bus_or_busbar_section_id: id of the bus or of the busbar section to which the injection will be connected with a closed disconnector.

  • position_order: in node/breaker, the order of the lcc converter station, will fill the ConnectablePosition extension

  • direction: optionally, in node/breaker, the direction of the lcc converter station, will fill the ConnectablePosition extension, default is BOTTOM.